16 BRIGGSandSTRATTON.COM
Engine Oil
The system is filled with synthetic oil (API SJ/CF 10W-30W).
This allows for system operation in the widest range of
temperature and climate conditions.
NOTE: The use of synthetic oil does not alter the required oil
change intervals described in the engine operator’s manual.
Shown here is the oil drain hose (B) and the oil filter location
(A) for the 12kW generator:
Shown here is the oil drain hose (B) and the oil filter location
(A) for the 15kW generator:
Changing Engine Oil
KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN USED
OIL TO COLLECTION CENTERS.
1. Confirm 15 Amp fuse is removed from control panel.
2. Place oil drain hose into an approved container.
3. Remove brass fitting from end of drain hose.
NOTE: Change oil while the engine is still warm from
running, as described in the engine operator’s manual.
4. When oil has drained, replace brass fitting on hose.
5. If all engine servicing is complete, replace 15 Amp fuse
in control panel and reset exercise timer. See
Setting
Exercise Timer in Operation.
To fill your engine with oil:
Follow the synthetic oil grade recommendation and oil fill
instructions given in the engine operator’s manual.
Battery
Servicing of batteries is to be performed or supervised
by personnel knowledgeable of batteries and the
required precautions. Keep unauthorized personnel away
from batteries.
Servicing the Battery
If it is necessary to service the battery, proceed as follows:
1. Set control board system switch to OFF.
2. Remove 15 Amp fuse from control panel.
3. Service or replace battery as required.
4. Connect red battery cable to battery positive terminal
(indicated by POSITIVE, POS, or (+)).
5. Connect negative battery cable to negative battery
terminal (indicated by NEGATIVE, NEG, or (-).
6. Ensure hardware on both positive and negative battery
terminals is secure.
7. Reinstall 15 Amp fuse in control panel.
8. Set generator’s system switch to AUTO.
9. Reset exercise timer. See Setting Exercise Timer.
DON’T POLLUTE. CONSERVE RESOURCES,
RETURN USED BATTERY TO RECYCLING
COLLECTION CENTER.
CAUTION: Avoid prolonged or repeated skin contact
with used motor oil.
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
•
•
WARNING: Battery posts, terminals and related
accessories contain lead and lead compounds,
chemicals known to the State of California to
cause cancer and reproductive harm. Wash hands
after handling.
/05*$&: Any attempt to crank or start the engine before
it has been properly serviced with the recommended oil
will result in equipment failure.
Refer to Maintenance in the Operator’s Manual and engine
manual for oil fill information.
Damage to equipment resulting from failure to follow this
instruction will void engine and generator warranty.
•
•